Installer Menu Options i-on160
Page 68
When logging into the i-on160EX Web Server you must key into the password
field the same code as you have programmed into the Installer Code field.
Keypad Text
If required the installer can key in a text message that appears on the first line
of the display in the standby screen. This could be, for example, the name of
the installer’s company. See page 12 for hints on editing text.
Remote needs Entry
Instead of using an entry timer triggered by a Final Exit zone to allow the user
to gain access to the control unit and unset the system, the user can employ a
remote control. To chose between either of these options select: System Options
– Remote needs Entry. The options available are:
Enabled The user must first tri
gg
er an entry zone and start the entry
timer before unsetting the system with a remote control.
Disabled The user can unset the system using a remote control without
first starting the entry timer.
PA Response
During a PA alarm the control unit starts communications (provided you have a
communication module fitted and enabled, or the communications outputs
wired to an appropriate communicator and correctly programmed). This option
controls the associated audible alarm.
Audible As well as starting communications the control unit starts PA
alarm tones from the keypads and loudspeakers, and activates
any siren outputs. The sirens follow the Siren Time (see page
69). The loudspeakers operate until a user silences the alarm.
Silent The control unit keeps the PA alarm silent: there are no alarm
tones from keypads or loudspeakers and any siren outputs or PA
outputs remain inactive. The control unit signals the PA using the
communications device(s).
Displayed All keypads display a PA alert message immediately (a user does
not have to key in their access code to see the message). If
more than one PA is active then the keypad display scrolls
through the alert messages at roughly one second intervals.
The control unit also starts PA alarm tones, activates any siren
outputs, and starts communications, as described for the
“Audible” option.
Note: All PAs are disabled when the system is in Installer Menu.
Auto Rearm
(Appears when if System Options – DD243 – Confirmation is set to “Off”, see page
62.)
To change the number of times that the system will re-arm when the siren
time expires select: System Options-Auto Rearm.
Select NEVER to make the system never re-arm (the system will go into alarm
once only). Select one of the other options to make the system re-arm once,