
The Installer Menu i-on160
Page 28
Panel Loudspeaker
Loudspeaker 1 (2)
Volume
Partitions 01...20
Yes Appears only in a Partitioned
system. Assigned to all
partitions
Entry Alarm Delay
Enabled This setting is required in
order to comply with EN50131
8.3.8.2.
Supervision
Enabled
Jamming
Enabled
Force Set
Off
Tamper Omit
Disabled This setting is required in
order to comply with
EN50131.
CSID Code
0000
Silence Alerts
User Code
Mains Fail Delay
0 minutes This setting is required in
order to comply with
EN50131.
Battery 2
Disabled
5 COMMUNICATIONS
ARC Reporting
Only visible when suitable
communications module fitted.
To comply with EN50131 you
must fit a communicator
module.
Call Mode
Enabled
his setting is required in
order to comply with
EN50131.
Phone book
empty
IP Network
Only visible when suitable
communications module fitted.
Account Number
000000 Part setting system has one
account number. A partitioned
system has one account
number per partition.
Report Type
Fast Format
Fast Format channels
Channel1: Fire
Channel 2: Panic alarm
Channel 3: Burglar
Channel 4: Open / Close
Channel 5: Zone Omit (System)
Channel 6: Alarm Abort
Channel 7: Confirmed Alarm
Channel 8: Technical Alarm
Channels 9 to 16: Not used
Appears only in a Level Setting
system.
Appears only when Report
Type=Fast Format
Comentarios a estos manuales