i-on160 Installer Menu Options
Page 53
The Setting Options sub-menu contains all the options to program entry, exit
and alarm response for a single alarm system with a Full Set and three Part
Set levels.
The Partitions sub-menu is divided into twenty partitions. Each partition
behaves like a complete, independent, alarm system. However, each partition
has only Full Set and one Part Set.
Table 2 on the next page shows the layout of both the Setting Options and the
Partitions menus. Since so many of the options work in the same way in both
of these menus, the table shows the page number where the description of
each option can be found.
Table 2. Setting Option and Partition Menus
3 SETTING OPTIONS
PAGE 3 PARTITIONS PAGE
Full Set Partition 1...20
Name 54 Name 54
Exit mode 54 Exit Mode 54
Settle time (see note 1) 54 Settle Time (see note 1) 54
Exit time (see note 2) 55 Exit Time (see note 2) 55
Entry time 55 Entry Time 55
Strobe on Set 55 Alarm Response 55
Strobe on Unset 55 Strobe on Set 55
Part Set B Strobe on Unset 55
Name 54 Part Set Exit Mode 54
Exit Mode 54 Part Set Settle Time (see
note 1)
54
Settle time (see note 1) 54 Part Set Exit Time (see
note 2)
55
Exit time (see note 2) 55 Part Set Entry Time 55
Entry time 55 Part Set Alarm Response 55
Alarm Response 55 Part Set Final Exit 55
Part Set Final Exit 55 Part Set Entry Route 56
Part Set Entry Route 56 Part Set Strobe Set 56
Strobe on Set 55 Part Set Strobe Unset 55
Strobe on Unset 55
Part C, D (Same as Part Set B) Full Set Link 56
Calendar Set 56 Calendar Set 56
Notes:
1. Appears only if Exit Mode is “Final Door”.
2. Appears only if Exit Mode is “Timed Exit” or “Silent Set”.
Notes for Part Set Options
In a Part Setting System, for Part Set B to work you must have at least
one zone with the attribute Part Set B = “Yes”, see page 36
In the same way For Part Set C to work you must have at least one zone
with the attribute Part Set C = “Yes”. For Part Set D to work you must
have at least one zone with the attribute Part Set D = “Yes”.
In a Partitioned System, for part set to work within a partition you must
assign the “Part Set” attribute to at least one zone belonging to the
partition.