2. If you are unsetting a partition and setting the same partition again then
you must program the setting event to occur at least 10 minutes after the
unsetting event.
System Options
This section of the Installer Menu contains a series of options that affect the
working of the alarm system as a whole.
Note: The default settings for these options are compliant with EN50131, see
page 23. Changes to some of the defaults may render the system non-
compliant.
Wired Zone Type
Normally the control unit asks you to select the zone wiring type when you
power up a new installation for the first time, or when you restore the control
unit to factory defaults (see page 9). This sub-menu lets you change the zone
wiring type for either the control unit or for the whole system. There are two
options:
Panel This option lets you chan
e the zone wirin
type for the control
unit.
System This option lets you change the zone wiring type for the whole
system.
For both options the choices available are: 4-wire CC, 4k7/2k2. 1k0/1k0,
2k2/2k2, or 4k7/4k7.
If you select “4 Wire CC” then the control unit and/or expanders provide five
wired zones, numbered 1 to 5.
There are several options of resistor values for FSL: the keypad display shows
the alarm contact resistor/end of line resistor values for each option.
If you select any of the Panel - FSL options then the control unit provides 10
wired zones, numbered 0 to 9.
If you select any of the System – FSL options then all wired expanders provide
10 wired zones, number 0 to 9.
You can change the wiring type of each wired expander individually, see page
40.
Note: Make sure that all zones are wired correctly for the selected wiring type.
See i-on160EX Installation Guide for wiring details.
User Access
To give users access to various system facilities select System Options – User
Access. Press the u or n keys to scroll up or down the list on the display. To
allow access press > repeatedly until “Yes” appears next to the selected
option. To deny access press > until “No” appears next to the selected option.
Press Y when you have finished.