i-on160 Installer Menu Options
Page 61
PA Keys Active
This option allows users to start an alarm from the keypads by pressing both
the Panic Alarm keys at the same time. This option applies to all keypads, both
radio and wired, and is not affected by allocating keypads to specific partitions.
Yes The PA keys on all keypads are functional.
No The PA keys are disabled.
Quick Set
Note: If you enable the quick set keys the control unit no longer complies with
EN50131.
This option controls the operation of the A, B, C or D keys.
Yes It is possible to set the alarm system by pressing A, B, C
or D without entering an access code.
No The user must enter an access code (or present a tag)
before pressing the A, B, C or D keys.
Quick Omit
This option allows users to omit a zone that is active (has it’s alarm contacts
open) while they are setting the system. The zone must have the Omittable
attribute (see page 36).
Yes By pressin
Y the user can set the system if there are
zones with the Omit Allowed attribute active.
No The user must
o to the Omit Menu to set the system if a
zone is active.
User Code Required
Use this option to ensure that an installer or maintainer cannot gain access to
program the system unless a user is present:
Yes After the installer/maintainer enters their access code, the
system asks for a user access code before allowing access
to the Installer Menu.
No The installer/maintainer can enter the Installer Menu by
simply keying in their own code.
User Reset
This menu option determines under what circumstances a user or the installer
can reset the system after an alarm.
Zone alarms
(Appears when if System Options – DD243 – Confirmation is set to “Off”, see page
62.)
Yes The user can reset the system after an alarm triggered by
a zone’s alarm circuit.
No The installer must reset the system after an alarm
triggered by a zone’s alarm circuit. See also “Remote
Reset” on page 97 .