Installer Menu Options i-on160
Page 44
When delivered from the factory, or if you restore the control unit to factory
settings, then all radio sirens belong to partition 1.
Once you have entered the Partitions option, press u or n to scroll through
the list of partitions followed by > or < to allocate/deallocate the radio siren to
each partition as necessary.
If you wish to allocate/deallocate the radio siren to many partitions you can
use the “All Partitions” option (in between partition 1 and 20 on the menu) to
either allocate or deallocate the radio siren to all partitions in one operation.
Once you have carried out this operation you can then scroll through the
partition list and change the allocation of the radio siren as necessary.
WAMs
The i-on160EX can operate up to 20 770r WAM modules. Although the WAM
provides five different modes, when working with an i-on160EX only mode 1,
repeater module, is relevant. The installer must select the repeater mode when
commissioning the WAM hardware.
When working as a repeater module the WAM repeats the signals from any
detectors within its range, amplifying them to a level that the i-on160EX
control unit can detect. This allows you to increase the area covered by
detectors.
Naming WAMs
Use the Edit WAM option to give each WAM a meaningful name. The name can
be up to 12 characters long.
Outputs
The i-on160EX control unit provides three different sets of outputs:
Dedicated Bell and Strobe outputs.
4 hardwired outputs.
16 plug-by outputs.
(See i-on160EX Installation Guide for the position of connectors.)
In addition to the outputs wired directly into the control unit, expanders also
provide outputs:
Each wired expander provides 4 outputs on its pcb.
Radio expanders each provide 10 radio output channels.
All these sets of outputs, both on the control unit and on expanders, can be
programmed as any of the output types listed on page 45.
The software within an i-on160EX control unit can handle up to 164 outputs in
total. If the number of physical outputs attached to the system exceeds this
maximum then the installer menu will not let you program some of those
outputs.
Bell and Strobe
You can program the behaviour of the dedicated Bell and Strobe outputs on
the control unit pcb with the following options:
Name You can assign a 12 character name to the Bell and Strobe