Installer Menu Options i-on160
Page 54
Options
Note: The default settings for these options are compliant with EN50131, see
page 23. Changes to some of the defaults may render the system non-
compliant.
Name
Use this option to give the Full Set, Part Set, or Partition a name. The
control unit displays this name to the user during setting.
Exit Mode
The exit modes available are:
Timed Set Use this option to make the system set after a
delay. Use the Exit Time menu (see page 55)
to choose the delay.
Final Door
Set
Use this option to complete setting the system
by closing a door fitted with a Final Exit zone
detector. Note that the exit time is infinite in
this option.
Note 1: If you wish to use Final Door Set exit
mode when part setting then:
a) Make sure that you include a zone with
the Final Exit type as one of the part set
zones.
b) Make sure you select “Final Door” in
Part Set Final Exit As (see page 55).
Note 2: If you wish to use Final Door Set exit
mode for a Partition then make sure you
include a zone with the type Final Exit in
the Partition.
Note 3: Do not try to make a PIR zone act as a
Final Exit. Radio PIR detectors have a
“lock out” period after each activation in
order to conserve battery power. When
you set (or part set) the system a PIR
may still be in lockout, during which it
cannot send a signal to complete the
setting process.
Instant Set The system sets immediately and without any
setting tone. The keypad(s) give confirmation
tone when the system is set.
Silent Set The system sets after the time programmed in
the Entry/Exit Time menu but does not give
any exit tones. When the system sets the
keypad gives a double beep confirmation tone.
The keypad(s) give a double beep confirmation
tone at the end of all setting modes.
Settle Time
This option allows you to define a time delay to allow detectors to settle
Vista de pagina 59