Cooper Security i-on160EX Guía de instalación Pagina 152

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 180
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 151
Step by Step Programming Procedures i-on160
Page 146
Press u or n to see other partitions.
8. Press Y to start the test.
The display shows for example:
24 Zone(s) to test
Zone 020
9. Tri
gg
er the alarm and tamper of each zone.
As you trigger the zones the top line of the
display shows the number of zones remaining
to test. The bottom line shows the first in a list
of zones that you have selected for testing.
Each zone that you test shows an “A” if you
have tested the Alarm contacts and a “T” if you
have tested the tamper.
The chime tone will sound for each zone you
activate if you have enabled Chime.
Press if you wish to see a list of the zones
not yet triggered.
23 Zone(s) to test
Zone 020 TA
10. Press u or n to scroll up or down the list of
zones.
Press X to finish the test.
To test the zones in an expander:
1. Enter the installer menu and select Test (see
steps 1 to 4 in “To start testing” on page 144).
TEST
Sirens & Sounders >
2. Press n until the display shows:
TEST
Walk Test >
3. Press Y.
The bottom line of the display gives you the
opportunity to turn the chime feature on or off.
WALK TEST
Chime On
4. Press < or > to toggle between Chime On or
Chime Off.
5. Press n until the display shows:
WALK TEST
Expanders >
6. Press Y.
The display shows:
WALK TEST EXPANDERS
W1-02 Wired Expandr>
7. Press Y to start the test.
The display shows for example:
24 Zone(s) to test
Zone 020