i-on160 Installer Menu Options
Page 49
Type: Active when: Assign to
Partitions?
Zone Omit
(System) (18)
(Operates only when DD243 is enabled.) In
the event of an unconfirmed alarm, the
system will rearm itself when the
confirmation timer expires. If the zone that
caused the unconfirmed alarm is still active
at the time of the rearm, the control unit
will omit that zone and activate the output.
The control unit will restore the zone and
output when a user or engineer resets the
system.
Yes
General Fault
(19)
There is any event that causes an alert
indication on the keypad. This includes:
RF Low Battery, RF Supervision, RF
Jamming, AC Fail, Battery Fault, PSU Fault,
Tamper, Masking
Yes
ATS Test (20) (This output type appears only for Plug-by
outputs.) The line fault input signal goes to
12V. The operation of the Line Fault input
and the ATS test output complies with the
requirements of BSIA form 175.
No
Siren (21) The control unit starts a full alarm, a panic
alarm or a fire alarm (the siren has a
distinctive tone during a fire alarm). The
control unit deactivates this output at the
end of the siren time. See page 69 to
choose the siren duration.
Yes
Strobe (22) a) The control unit starts a Full alarm,
panic alarm or fire alarm. The output
remains active until the user disarms the
system.
b) Setting or unsetting, if you have
selected “strobe on set” and/or “strobe on
unset”, see pages 55 and 55.
Yes
Entry Exit Follow
(23)
The entry or exit time starts and
deactivates at the end of the entry/exit
time, or if the entry/exit time is
terminated. The output can be used for a
separate entry/exit buzzer. Note that the
output does not operate if the exit mode is
silent set or instant set.
Yes
Armed (24) The system (or partition) is full or part set. Yes