i-on160 Step by Step Programming Procedures
Page 109
Press > or < to allocate or remove partitions as
required.
Partition 2 Yes
12. Press Y to confirm your changes.
Exp. W1-01
Partitions >
13. Carry on with any other programming that you
need to do. DON’T FORGET to leave the Installer
Menu in order to save the changes you have
made (see page 7 ).
Changing the Wiring Type of Wired Expanders
1. Enter Installer Menu.
INSTALLER MENU
Detectors/Devices >
2. Press Y.
DETECTORS/DEVICES
Detectors >
3. Press n until the display shows:
DETECTORS
Wired Expanders >
4. Press Y .
WIRED EXPANDERS
Address Bus Device >
5. Press n .
WIRED EXPANDERS
Edit Expander >
6. Press Y .
EDIT EXPANDER
Exp. W1-01 (W10)>
7. Press u or n to select the expander that you
wish to edit. Then press Y.
The bottom line of the display shows “Name”.
Exp. W1-01
Name >
8. Press n until the display shows:
Exp. W1-03
Wired zone type >
9. Press Y .
The bottom line of the display shows the current
wiring type of the expander. A “*” at the
beginning of the line acts as a reminder if you
scroll away and back again See page 40 for an
explanation of the wiring types.
Exp. W1-03
*4-wire CC
10. Press u or n to show the wiring type you wish
to choose.
Exp. W1-03
2-wire FSL 2K2/4K7
11. Press Y .
The display asks you to confirm your choice:
Exp. W1-03
Are you sure?
12. Press Y to confirm your choice.
Exp. W1-03