Step by Step Programming Procedures i-on160
Page 144
g) Carry on with any other programming that you
need to do. DON’T FORGET to leave the
Installer Menu in order to save the changes you
have made (see page 7 ).
OR IF DD243 Confirmation is OFF then:
a) Press n until the display shows:
SYSTEM OPTIONS
User reset >
b) Press Y.
USER RESET
Zone alarms Yes
c) Press > until the display shows:
USER RESET
Zone alarms No
d) Press Y.
SYSTEM OPTIONS
User Reset >
e) Carry on with any other pro
rammin
that you
need to do. DON’T FORGET to leave the
Installer Menu in order to save the changes you
have made (see page 7 ).
Testing
To start testing
1. Make sure the system is idle.
i-on160EX
13:25 16/3/2010
2. Enter Installer Menu.
INSTALLER MENU
Detectors/Devices >
3. Press u until the display shows:
INSTALLER MENU
Test >
4. Press Y.
TEST
Sirens & Sounders >
5. Press n until the display shows the part of the
system that you wish to test.
To walk test
To test every zone in the whole system:
1. Enter the installer menu and select Test (see
steps 1 to 4 in “To start testing” above).
TEST
Sirens & Sounders >
2. Press n until the display shows:
TEST
Walk Test >
3. Press Y.
The bottom line of the display gives you the
opportunity to turn the chime feature on or off.
WALK TEST
Chime On
Comentarios a estos manuales