i-on160 Installer Menu Options
Page 37
Chime
When enabled by the user, the system gives a non-alarm warning tone
when any zones programmed as ‘Chime’ are opened. This facility operates
only while the system is unset.
Soak Test
Use this zone attribute if you want to place under long term test a
detector that you suspect is giving false alarms. Zones with this attribute
are disabled for 14 days after you return the control unit to user/unset
mode. If the zone remains inactive for the whole fourteen days then after
midnight on the 14th day the control unit returns the zone to normal use.
If the zone is activated during those 14 days while the system is set then
the control unit logs the event as a “Soak Test Fail Z1-ee-nn” (ee is the
bus device number and nn is the zone number, see page 17) without
sounding any sirens or starting communications. The control unit also
lights the red LEDs around the navigation key on the keypad to alert the
user. An installer must key in their access code to reset the alert.
You can apply the soak test attribute to Normal Alarm, Entry Route and
Tamper zone types.
During setting the keypad displays a brief message to inform the user that
one or more zones are in soak test.
Double Knock
Zones programmed with this attribute will cause an alarm only if the zone
is EITHER triggered, restored and triggered again within a five minute
period, OR if the zone remains active for 10 seconds.
You can apply the Double Knock attribute to the Normal Alarm and Entry
Route zone types.
Part Set B
(Not visible in a partitioned system.) When a user presses button B (part
set), the control unit sets only those zones where the Part Set B attribute
= “Yes”. (See also “Part Set Exit Mode” on page 54 ).
Part Set C
(Not visible in a partitioned system.) When a user presses button C the
control unit sets only those zones where Part Set C attribute = “Yes”.
Part Set D
(Not visible in a partitioned system.) When a user presses button D the
control unit sets only those zones where Part Set D attribute = “Yes”.
Part Set
(Not visible in a Part Setting system.) When a partition is Part Set, zones
in that partition with this attribute are set. Note that if a zone is in more
than one partition, all partitions have to be set or part set before this zone
will be set.
Omittable
This attribute applies to the following zone types only: Normal Alarm,
24hr, Technical, Entry Route, Tamper, External PSU A/C Fail, External PSU
Battery Fault, External PSU Low Volts and External PSU Fault.
A) When a zone has this attribute, a user can omit it before
setting the
system.
B) If a user tries to set the system when a zone with this attribute is open