Appendix II i-on160
Page 158
System Options Wired Zone Type Select FSL if using all wired detectors
DD243 (for UK only) Confirmation = On
•
Confirmation
Time
30 mins
After Entry
2 zones
•
Entry keypad
Lock
On
Sounder on
Unconfirmed
Siren on
Unconfirmed
•
Unconfirmed
rese
User
Confirmed Reset
Installer
Keypad Text Enter Name of installer company
Siren Delay (default 0 mins)
Siren Time
default 15 mins
Force Set Off
CSID Enter 4 digit ARC Scantronic reset code (if
required)
Silence Alerts User
User Programming
User Code Type Partitions
01 1234 Master User Whole system – P2 + P3
02 2222 Partition user P2 (Factory)
03 3333 Partition user P3 ( Office)
User Operation
To set:
Full System User 01 enters code or Prox + 3
(User 01 can select an individual Partition or full
set the whole system.)
Factory only
(Partition 2)
Partition 2 User enter Code or Prox in Keypad 2
Office only
(Partition 3)
Partition 3 User enter Code or Prox in Keypad 1
To Unset:
First user to enter keys in their code or presents a
Prox tag
If User 02 (a member of the Factory department) sets their Factory partition
and the Office partition is already set, then the common foyer area will also
start to set. When the user closes the Front Door (zone 1) the whole system
sets and the alarm response is raised to Full alarm (Siren + Comms).
The same thing will happen if User 03 sets the Office partition when the
Factory partition is already set.