i-on160 The Installer Menu
Page 27
4 SYSTEM OPTIONS
Wired Zone type
To comply with EN50131
select this option manually
during initial power up.
Panel Zones
2 Wire FSL 2k2/4k7
All Zones
2 Wire FSL 2k2/4k7
User Access
PA keys active
No
Quick Set
No This setting is required in
order to comply with
EN50131.
Quick Omit
No
User code req’d
Yes
User reset
Zone alarms
7
Yes This option does not appear if
DD243 Confirmation is ON
Zone tampers
Yes For INCERT approval set to
NO.
System tampers
No
DD243
Confirmation
On DD243 is a UK requirement. If
this option is disabled in non-
UK countries then the control
unit will still comply with
EN51031. This menu is visible
only when System Options –
R
estore Defaults
– Country
de
f
aults is set to “UK”.
Confirmation time
30 mins
After Entry
2 zones
Entry Keypad Lock
Off
Sounder on
Unconfirmed
Siren on
Unconfirmed
Unconfirmed reset
User
Confirmed reset
Use
r
Masking
Off
Language
English
Restore Defaults
Country defaults
Staged defaults
Factory defaults
Installer Name
Installer”
Installer Code
7890” Grade 2, “567890” Grade 3
Keypad text
i-on160EX
Remote Needs Entry
Disabled
PA Response
Audible
Auto Rearm
Never This setting is required in
order to comply with
EN50131.
Appears only when System
Options – DD243 –
Confirmation is “off”.
Siren Delay
0 min
Siren Time
15 minutes
T
o comply with EN50131-1
Clause 8.6 minimum is 90s,
maximum is 15mins.