4. Programming
496964 Page 91
24 Strobe Set C: active for 10 seconds after Partition C is set.
25 Strobe Set D: active for 10 seconds after Partition D is set.
26 Pulse Set 1: active for time set by Command 170.
27 Pulse Set 2: active for time set by Command 170.
28 Pulse Set 3: active for time set by Command 170.
29 Pulse Set 4: active for time set by Command 170.
30 Pulse Unset 1: active for time set by Command 172.
31 Pulse Unset 2: active for time set by Command 172.
32 Pulse Unset 3: active for time set by Command 172.
33 Pulse Unset 4: active for time set by Command 172.
34 Fire: active during a Fire alarm.
35 PA: active during a PA.
85: Burglar Communications Rearm
This Command determines what happens to the "Burg" communications
output (or channel) at the end of the bell run time.
Option
0 Latched. The output stays active until an engineer or user resets the
system.
1 Rearm. The system turns off the "burg" channel when the bell run time
has expired. Once the channel is inactive, the system is ready to
report any new alarm.
Note: If Alarm Abort is enabled (Command 36, option 1), the "burg" channel
restores if the user unsets the system.
86: Dual Ply Entry Warning
Note: Disable Alarm Confirmation (Command 89) to use this Command.
If users habitually exceed the Entry Time, select option 1 to add a 30-second
extension during which the internal sounders give a warning tone. Select
option 0 (the default value) to disable Dual Ply Entry.
The extension applies to both full and part setting.
Note: Using Dual Ply Entry is not recommended because it does not comply
with industry standards for alarm system operation.