4. Programming
Page 54 496964
Command Key in:
151 Plug-by Communications Output 1
(page 108)
151YnnY
nn = 00 Not Used
01 Fire
Y
02 PA
03 Burglar
04 Open/Closed
05 Alarm Abort
06 Technical Alarm
07 Alarm Confirmation
08 RF Low Battery
09 RF Supervision Loss
10 RF Jamming
11 AC Fail
12 Tamper Alarm
13 Open
14 Close
15 Zone Omitted
16 Medical
17 Keybox
18 Anti-Mask
19 Smoke Detector
20 Comms Acknowledge
21 Battery Fault
22 System Alarm
In a partitioned system:
23 Alarm Partition A
24 Alarm Partition B
25 Alarm Partition C
26 Alarm Partition D
27 Not used
28 Not used
29 Not used
30 Pulse Set 1
31 Pulse Set 2
32 Pulse Set 3
33 Pulse Set 4
34 Pulse Unset 1
35 Pulse Unset 2
36 Pulse Unset 3
37 Pulse Unset 4
152 Plug-by Communications Output 2
(page 108)
152YnnY
n = See Command 151 for a list of options.
Default is 02 PA
Y
153 Plug-by Communications Output 3
(page 108)
153YnnY
n = See Command 151 for a list of options.
Default is 03 Burglar
Y
154 Plug-by Communications Output 4
(page 108)
154YnnY
n = See Command 151 for a list of options.
Default is 04 Open/Close
Y
155 Plug-by Communications Output 5
(page 108)
155YnnY
n = See Command 151 for a list of options.
Default is 15 Zone Omitted
Y
156 Plug-by Communications Output 6
(page 108)
156YnnY
n = See Command 151 for a list of options.
Default is 05 Alarm Abort
Y
Command Key in:
157 Plug-by Communications Output 7
(page 108)
157YnnY
n = See Command 151 for a list of options.
Default is 07 Confirm
Y
158 Plug-by Communications Output 8
(page 108)
158YnnY
n = See Command 151 for a list of options.
Default is 06 Technical
Y
159 Invert Plug-by Logic (page 109)
159YnnY
n = 0 Off (do not invert logic)
Y
1 On (invert logic)
C160-4 are valid only if C89 is set to option 1.
160 Confirmed Alarm Timer (page 109)
160YnnnY
nnn = a time from 001 to 999 minutes 030 minutes
161 Internal Sounder (page 109)
161YnY
n = 0 Sounder on Unconfirmed Alarm
Y
1 Sounder on Confirmed Alarm
162 External Sounder (page 110)
162YnY
n = 0 Sounder on Unconfirmed Alarm
Y
1 Sounder on Confirmed Alarm
163 Confirmed Alarm during Entry (page
110)
163YnY
n = 0 Never (no zones)
Y
1 One zone
2 Two zones
164 User Reset after Confirmed Alarm
(page 110)
164YnY
n = 0 User/Engineer
Y
1 User/User
2 Engineer/Engineer
165-9 These commands are not used.
170 Pulse Set 1 to 4 Duration (page 111)
170Y
nnYnnY
nnYnnY
nn = 00 to 12 seconds 01 seconds
171 Pulse Set Allocation (page 111)
171YnY
nYnYnY
n = A Level/Partition A abcd
B Level/Partition B
C Level/Partition C
D Level/Partition D
172 Pulse Unset 1 to 4 Duration (page
111)
172Y
nnYnnY
nnYnnY
nn = 00 to 12 seconds 01 seconds
173 Pulse Unset Allocation (page 111)
173YnY
nYnYnY
n = A Level/Partition A abcd
B Level/Partition B
C Level/Partition C
D Level/Partition D
174 Fire Pulse Unset (page 111)
174YnY
nYnYnY
n = 0 Off
1 On
Y
175 PA Pulse Unset (page 111)
175YnY
nYnYnY
n = 0 Off
1 On
Y
176-9 These commands are not used.