4. Programming
Page 116 496964
200: Forbikobler Entry Timer
This Command sets the interval between a user entering the premises
through a Forbikobler entrance and an alarm going off, using one of the
independent entry timers configured with Commands 201 to 204. Any of the
entry timers can be assigned to any Forbikobler entrance. Entering the entry
code into the Forbikobler unit starts the selected entry timer.
Option
1 Entry Timer 1
2 Entry Timer 2
3 Entry Timer 3
4 Entry Timer 4
201 to 204: Entry Timers 1 to 4
Entry timers set the interval between a user entering the premises and an
alarm going off. There are four independent entry timers so that you can set
different intervals for different entrances, reflecting the time required to
complete each entry route.
Note: These replace the level-specific timers available on earlier control units
(formerly set with Commands 43, 64, 74 and 78). They provide a more
flexible approach to timed entry routes, enabling any timer to be selected
for any entrance.
Each entry timer can be assigned to any zone of types FE (Final Exit), ER
(Entry Route) and FB (Forbikobler), using the zone programming Commands
01 to X40 (see page 61). Set zone attribute X7 to a value between one and
four to select the required entry timer. Opening the zone starts the selected
entry timer.
Option
1 10 seconds
2 20 seconds (default)
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Note: By default, Entry Timer 1 is assigned to all relevant zones.