3. Installation
496964 Page 43
Comms O/P1 (Brown) -ve applied (+ve removed) in alarm
Comms O/P2 (Orange) -ve applied (+ve removed) in alarm
Comms O/P3 (Yellow) -ve applied (+ve removed) in alarm
Comms O/P4 (Green) -ve applied (+ve removed) in alarm
Comms O/P5 (Blue) -ve applied (+ve removed) in alarm
Comms O/P6 (Purple) -ve applied (+ve removed) in alarm
Comms O/P7 (White) -ve applied (+ve removed) in alarm
Comms O/P8 (Grey) -ve applied (+ve removed) in alarm
Line Fail input (White/Brown) +12V applied to indicate telephone line fail.
Tell Back input (White/Orange) +12V appied to change from engineer to customer reset.
0V (Black)
12V (Red)
Com Connector Cable, Part No. 485210
Figure 32. Communications Wiring Harness
4. Plug the Communication Wiring Harness onto the communications
connector on the main PCB (see Figure 5).
5. On the 9751, re-fit the PCB to the support pillars. Secure the PCB to the
support pillars with the screws provided (Figure 33). Make sure that the
bottom left corner of the PCB is seated on its support pillar.
Figure 33. Fitting Control Unit PCB (9751)
If the system has already been installed:
6. Re-connect the battery.
7. Fit the case lid.
8. Apply mains power.
9. Test communicator operation (using Commands 151 to 158).