496964 Page 47
4. PROGRAMMING
Entering Programming Mode
"3. Installation – Initial Power Up" on page 44 describes how to enter
programming mode for the first time in a new installation. To enter
programming mode at any other time:
1. Make sure the system is unset.
Note: If you have selected defaults for Finland, Norway, Sweden or Denmark
(Command 0), you must enter a valid user code at this point.
2. Press 0, then key in the Engineer Code (default 7890).
The display shows:
Installer Mode
You are now in programming mode.
While the system is in programming mode, all keypads except the one that
you are using will be locked and will display "Busy".
Using Programming Commands
When delivered from the factory, the control unit already has default program
settings. To change the default programming, you must be in programming
mode. Then:
1. Key in the appropriate Command number and press Y.
The display shows the current value of the Command.
2. Key in digits to select the value you require.
The display shows the new value.
3. Press Y to store the new value of the Command.
If at any time you change your mind, repeat steps 1 to 3. The table on the
following pages shows the Commands and their values. "Y" to the right of a
value shows that it is the factory default. The default access codes are:
Engineer Code
7890
Access Code User 1 1234
Access Code Users 02 to 16
X 002 .... X 016
(inactive)
Duress Code
X017
(inactive)
Note:
To activate the inactive Access Codes (02 to 16) and Duress Code,
USER1 must change the defaults to the required four-digit numbers.
The "9851, 9752, 9751 User Guide" explains how to do this.