4. Programming
Page 96 496964
To make static test call at regular intervals, you have two options:
Cnn To make a static test call every nn hours, press C and then key in a
number between 01 and 24 to select the interval in hours. For example,
key in 12 to program the control unit to make a call every 12 hours.
Dnn To make a static test call every nn days, press D and then key in a
number between 01 and 28 to select the interval in days. For example,
key in 07 to program the control unit to make a call every 7 days.
The control unit adjusts the timing of calls by up to 16 minutes (exact interval
chosen at random) to ensure that the ARC is not overwhelmed by a flood of
test calls from systems that have all been set with the static test options.
Note: Cooper Security recommends that you choose either Static Test Call
(105) or Dynamic Test Call (108), but not both at the same time.
106: Line Fault Response
This Command sets how the control unit responds when it detects a fault on
an attached telephone line. Its exact response depends on whether the
system is set or unset:
Option
0 Disabled. The control unit does not monitor the telephone line.
1 Audible.
If the system is unset, the control unit logs the event and the keypads
emit a short audible tone every minute. Entering a valid access code
silences the sounders and the keypad displays indicate a telephone
line fault. The system can be set again with the line fault present.
If the system is set, the control unit logs the event but the keypads do
not emit a tone or display a message. If the line is out of order when
an alarm occurs, the control unit cancels any programmed Bell Delay.
Note: Audible response is the NACOSS recommendation for line faults.
2 Silent.
If the system is unset, the control unit logs the event and the keypad
displays indicate a telephone line fault (without giving any audible
warning). The system may be set again with the line fault present.
If the system is set, the control unit logs the event but the keypads do
not display a message. If the line is out of order when an alarm
occurs, the control unit cancels any programmed Bell Delay.
107: Not used
This command is not used.