3. Installation
Page 38 496964
Safety Notice
Figures 28 and 29 identify connectors for Safety Extra-Low Voltage (SELV)
and Telecommunications Network Voltage (TNV) circuits on the control unit's
main PCB. These terms are used in accordance with the definitions in Safety
Standard EN60 950.
The Installer must ensure that TNV terminals are connected only to other
circuits designated as TNV circuits (for example, the PTSN) and that SELV
terminals are connected only to other circuits designated as SELV circuits.
Strict adherence to the installation instructions will ensure that the equipment
continues to comply with the safety regulations to which it was approved.
CCT1
CCT2
CCT3
CCT4
CCT5
CCT6
CCT7
CCT8
+
LS
12V AUX
0V
12V AUX
0V
A/T
CLK DATA
0V
12V
Keypad Connector
S.E.L.V. cct
1. Main connector (SELV) 6. Local Downloader connector – 9752 only (SELV)
2. Keypad connector (SELV) 7. Lid tamper connector – 9752 only (SELV)
3. Telephone line connector (TNV) 8. Battery connector (SELV)
4. RJ11 connector (TNV) 9. 21VAC from transformer (SELV)
5. Wire in comms connector (SELV)
Figure 28. SELV and TNV connectors on the 975x