4. Programming
Page 52 496964
Command Key in:
81 Output 1 Type (page 89)
81YnY
n = Where n is one of:
In a single or partitioned system:
00 Bell
Y
01 EE Follow
02 Armed Lamp
03 Set Latch
04 Shock Sensor Reset
05 Walk Test
06 Ready Lamp
07 24-hour Alarm
08 Strobe
09 Smoke Sensor Reset
10 French Siren Test
11 Strobe Set (any partition)
12 Pulse Set 1
13 Pulse Unset 1
14 Alarm Confirmation
15 Set Complete 1
16 Unset Complete 1
17 System Bell
In a partitioned system:
18 Bell Partition A
19 Bell Partition B
20 Bell Partition C
21 Bell Partition D
22 Strobe Set Partition A
23 Strobe Set Partition B
24 Strobe Set Partition C
25 Strobe Set Partition D
26 Pulse Set 1
27 Pulse Set 2
28 Pulse Set 3
29 Pulse Set 4
30 Pulse Unset 1
31 Pulse Unset 2
32 Pulse Unset 3
33 Pulse Unset 4
34 Fire
35 PA
82 Output 2 Type (page 89)
82YnY
n = See Command 81 for a list of options.
Default is 08 Strobe
83 Output 3 Type (page 89)
83YnY
n = See Command 81 for a list of options.
Default is 03 Set Latch
84 Output 4 Type (page 89)
84YnY
n = See Command 81 for a list of options.
Default is 03 Set Latch (9851 only)
85 Burg Communication Rearm (page
91)
85YnY
n = 0 Latched
Y
1 Rearm
86 Dual Ply Entry Warning (page 91)
86YnY
n = 0 Off
Y
1 On (not recommended)
87 Keypad Dual Key Alarm (page 92)
87YnY
n = 0 Off
Y
1 On (PA, Medical and Fire enabled)
Command Key in:
Note: This also enables a PA from
keyswitches.
88 This command is not used.
89 Alarm Confirmation (page 92)
89YnY
n = 0 Confirm off (default for rest of world)
Y
1 Confirm on (default UK only)
90 Event Log (page 129)
90YnY
Shows the most recent event in the log
n = 0 Print log (9851 only)
1 View earlier events
3 View later events
4 First event
6 Last event
7 Toggle printer on/off (9851 only)
8 Print configuration (9851 only)
X Cancel viewing
Y Toggles time/date display
91 Test Output 1 (page 132)
91Y
Output 1 operates, press X or Y to end
test
92 Test Output 2 (page 132)
92Y
Output 2 operates, press X or Y to end
test
93 Test Output 3 (page 132)
93Y
Output 3 operates, press X or Y to end
test
94 Test Internal Sounder (page 132)
94Y
Internal sounders operate, press X or Y
to end test
95 Test Keypad Sounder (page 132)
95Y
Keypad sounders operate, press X or Y
to end test
96 Test Output 4 – 9851 only (page 132)
96Y
Output 4 operates, press X or Y to end
test
97 Engineer Walk Test (page 133)
97Y
Zn indication and Chime operate when
circuit open
X End Walk Test
98 Load Full Defaults (page 93)
98Y1YnY
n = 0 Single system
Y
1 Partitioned system
99 Leave Programming Mode (page 93)
99YY
100 This command is not used.
C101-158 are for programming communications.
101 Call Mode (page 94)
101YnY
n = 0 Disabled
Y
1 Single
2 Alternate
3 Dual
102 This command is not used.
103 Reporting Type (page 95)
103YnY
n = 0 Fast format
Y
1 Contact ID
2 SIA I
3 SIA II
4 SIA 3
5 Extended SIA 3
6 Home "beep"
104 This command is not used.