4. Programming
496964 Page 123
Lobby
Common Area
Office A
Partition A
Office B
Partition B
KPD KPD
Z1
Z2
Z3
Z4
Figure 38. Using a Private Door
Partition A has a separate exit guarded by a Final Exit zone (zone 4). Partition
B is set. User A starts setting at their keypad and then leaves by their private
door on zone 4. The control unit is expecting to see zone 1 close in order to
complete setting Partition A and the common area. However, since zone 1
has not opened and closed, the control unit does not set either Partition A or
the common area.
In general, when using Final Exit, make sure that the exit route is always
shared by increasing the number of partitions. Figure 39 shows an extreme
example.
Common Area
Common Area
Common Area
Partition A Partition B Partition C Partition D
KPD KPD KPD KPD
Figure 39. Arranging Shared Exit Routes