496964 Page 115
191 to 198: Fast Format Channels
If Fast Format reporting is selected (Command 103, option 0) Commands 191
to 198 allow you to assign one of the following events to each output.
Command 191 controls output 1, 192 output 2, and so on up to Command
198 which controls output 8. Each Command has the same options:
00 Not Used 19 Smoke Detector
01 Fire 20 Comms Acknowledge (see Note)
02 PA 21 Battery Fault
03 Burglary 22 System Alarm
04 Open/Close 23 Alarm Partition 1
05 Alarm Abort 24 Alarm Partition 2
06 Technical Alarm 25 Alarm Partition 3
07 Alarm Confirmation 26 Alarm Partition 4
08 RF Low Battery 27 Not used
09 Supervision Loss 28 Not used
10 RF Jamming 29 Not used
11 AC Fail 30 Set OP 1
12 Tamper Alarm (day tamper) 31 Set OP 2
13 Open 32 Set OP 3
14 Close 33 Set OP 4
15 Zone Omitted 34 Unset OP 1
16 Medical Assistance 35 Unset OP 2
17 Key Box 36 Unset OP 3
18 Anti-Mask 37 Unset OP 4
Notes:
1. 13 Open and 14 Close provide the same functions as 4 Open/Close,
but on two separate channels.
2. 15 Zone Omitted – the control unit sends this signal for five seconds
when a user omits a zone.
3. The control unit sends 08 RF Low Battery when the radio detector with
a low battery causes an alarm or sends a supervision signal. To enable
this facility in day mode set Menu 37 to option 1.
4. The control unit delays reporting/logging either mains loss, or exiting
engineering with mains loss, by 15-18 min (chosen at random). If you
select a Scandinavian country in Command 0, the control unit waits at
least 60 minutes before reporting.
199: Display Zone Circuit Resistance
For information on this command, see "5.Testing".