4. Programming
Page 50 496964
Command Key in:
42 Bell Duration (page 76)
42YnY
n = 1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes
6 20 minutes
Y
43 This command has been replaced by
Command 201.
44 Level/Partition A Exit Time (page 77)
44YnY
n = 1 10 seconds
2 20 seconds
Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
45 Entry/Exit Tone Volume (page 77)
(In a partitioned system, this Command
is available only for Partition A)
45YnY
n = 0 No Entry/Exit tone from sounder
n EE tone volume (1=low, 9=max) 5
46 Tamper Alarm Response – single
system only (page 77)
46YnY
n = 0 Internal sounders only
1 Keypad sounders only
2 Internal and keypad sounders
Y
47 Partition A Alarm Response –
partitioned system only (page 77)
47YnY
n = 0 Keypad sounders only
1 Local (all sounders, no comms)
2 Full (all sounders and comms)
Y
48 Lockout Keypads During Entry (page
78)
48YnY
n = 0 No
1 Yes
49 This command is not used.
50 CSID Code (page 78)
50YnnnnY
nnnn = Central Station ID for remote reset none
51 Set Time and Date (page 79)
51YddY
mmYyyY
hhYmmY
dd Day of the month (01–31)
mm Month of the year (01–12)
yy Year (00–99)
hh Hour of the day (01–23)
mm Minute of the hour (01–59)
52 Omit Alarm (page 79)
52YnY
n = 0 Alarm contacts only
Y
1 Alarm and tamper contacts
53 Abort Reset (page 79)
53YnY
n = 0 Use option selected in Command
33
Y
1 User reset after an aborted alarm
54 BVVO Supervision – not 9751 (page
80)
54YnY
n = 0 Disabled
Y
1 Enabled
55 This command is not used.
Command Key in:
56 4/6 Digit Access Codes – not 9751
(page 80)
56YnY
n = 0 Four-digit codes
Y
1 Six-digit codes
57 Battery Load Test – not 9751 (page
80)
57YnY
n = 0 Disabled
Y
1 Enabled
58 BVVO Tamper Indication – not 9751
(page 80)
58YnY
n = 0 User Reset
Y
1 Installer Reset
59 External Sounder Tamper (page 81)
59YnY
n = 0 Negative voltage tamper return
Y
1 End of line 2k2 resistor
60 Level/Partition B Final Exit Operation
– single system only (page 81)
60YnY
n = 0 B=FE = FE (Final Exit)
Y
1 B=FE = NA (Normal Alarm)
61 Level/Partition B Entry Route
Operation – single system only (page
81)
61YnY
n = 0 B=ER = ER (Entry Route)
Y
1 B=ER = FE (Start entry timer)
62 Level/Partition B Exit Mode (page 81)
62YnY
n = In a single system:
0 Timed low tone on setting
Y
1 Instant (no exit tone)
2 Silent (double "beep" after exit time)
3 Sets exit mode the same as Level A
In a partitioned system:
0 Timed full tone on setting
Y
1 Terminated (terminated by button)
2 Final Door (last door has a detector)
3 Instant (no exit tone)
4 Silent (double "beep" after exit time)
5 Lock Set (terminated by lock switch)
63 Level/Partition B Alarm Response
(page 82)
63YnY
n = In a single system:
0 Keypad sounders only
1 Internal and keypad sounders
Y
2 Local (all sounders, no comms)
3 Full (all sounders and comms)
In a partitioned system:
0 Keypad sounders only
1 Local (all sounders, no comms)
2 Full (all sounders and comms)
Y
64 This command has been replaced by
Command 202.
65 Level/Partition B Exit Time (page 83)
65YnY
n = 1 10 seconds
2 20 seconds
Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Vista de pagina 57