3. Installation
Page 30 496964
Connecting Detector Circuits
The connectors for the detector circuits, or zones, are on the left hand edge of
the main PCB in the control unit. The table below summarises the number
and type of zones that can be connected to each model of control unit. Use
Command 21 to configure the connectors to the required wiring type.
Model Connectors Zones Wiring Types
9751 14 8
8
24
four-wire CCL with common tamper
two-wire FSL
two-wire FSL + expanders
9752 14 8
8
32
four-wire CCL with common tamper
two-wire FSL
two-wire FSL + expanders
9851 24 8
16
16
40
four-wire CCL with individual tampers
two-wire FSL
two-wire EOL
two-wire FSL + expanders
CCL Connections
Figures 18 and 19 shows how to connect four-wire CCL zones with common
and individual tampers. The control unit provides enough connectors for eight
CCL zones. If you wish to connect more, you must fit one or more hardwired
expanders (see "Connecting Expanders" on page 32).
1
2
3
Zone 1
Zone 2
Global Anti-tamper
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Tamper loop
Zone 1
Zone 2
Alarm contacts
Alarm contacts
Figure 18. CCL Connections (common tamper – 975x)
Alarm contacts
Zone 1
Tamper contacts
1
3
2
4
Zone 2
Zone 1
Zone 2
Figure 19. CCL Connections (individual tamper – 9851)