Page 74 496964
39: Level/Partition A Exit Mode
Use this Command to select the exit mode for Full Set or Partition A.
Option
0 Timed. Use this option if the system sets after an exit time selected
using Command 44. If an Exit Terminate button is fitted, the user may
use it to shorten the exit time.
1 Terminated. Use this option if the user completes setting the system
by pushing an Exit Terminate button connected to a keypad. The exit
time is infinite in this option. The system sets seven seconds after the
completed action. Settling time is controlled by Command 182 (see
page 113).
2 Final Door Set. Use this option to complete setting of the system by
closing a door fitted with a Final Exit zone detector. The exit time is
infinite in this option. The system sets seven seconds after the
completed action. Settling time is controlled by Command 182 (see
page 113).
3 Single system: Lock Set (see point 5 below).
Partitioned System: Instant Set. Use this option to make the system
set without delay or exit tone.
4 Silent Set (partitioned system only). The system sets after an exit time
programmed in Command 44 but does not emit an exit tone. When
the system sets, the keypad gives a double "beep".
5 Lock Set (partitioned system only). To use this option, you must install
a lock switch and connect its contacts to the ET terminals of a keypad
(see Figures 16 and 17 on pages 28 and 29). This facility is available
on keypad software version 1.4.2 onwards.
Do not assign the keypad to more than one partition. Do not connect
more than one lock switch (or any other device) to the keypad ET
terminals. In a single system, do not attempt to fit two lock switches.
To set the system, the user first enters their access code at a keypad
or operates a keyswitch. The control unit starts to emit the exit tone.
The exit time is infinite in this option. The user then operates the Final
Exit zone and turns the key in the lock switch to "locked". The system
sets seven seconds after the lock switch contacts open. Settling time
is controlled by Command 182 (see page 113).