3. Installation
Page 32 496964
EOL Connections (9851 only)
Each EOL zone is a two-wire closed loop that uses a single 2K2 resistor fitted
in series with the alarm contacts to differentiate between "Circuit" and
"Tamper" signals. Figure 22 shows how to connect two EOL detectors to
adjacent zones. Each detector is wired in series with a common anti-tamper
circuit, which is connected to the terminals marked "3" and "4". You must
connect a single 2K2 resistor in series with the anti-tamper circuit.
Zone 1
Zone 3
Zone 4
Zone 2
2K2 EOL
Alarm contacts
2K2 EOL
2K2 EOL
Alarm contacts
Global anti Tamper Loop
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Zone 5
Zone 6
Zone 7
Zone 8
Figure 22. EOL Connections
Connecting Expanders
Figure 23 shows how to connect a 9954 hardwired expander to the control
unit.
0V 12V CLK DATA
To other keypads
12V
0V
DATA
CLK
Expander
Control Unit
Figure 23. Connecting a 9954 Expander
When fitting a 9954 hardwired expander, make sure that you place the jumper
link on the expander in the correct position to select either four-wire CCL, or
two-wire FSL or EOL.