4. Programming
Page 86 496964
73: Level/Partition C Alarm Response
This Command sets the Alarm Response for Level or Partition C.
In a single system, the options are:
Option
0 Keypad sounders only.
1 Internal sounders and keypad sounders.
2 Local alarm (internal and external sounder only).
3 Full alarm (communication and internal/external sounders).
In a partitioned system, the options are:
Option
0 Keypad sounders only.
1 Local alarm (internal and external sounder only).
2 Full alarm (communication and internal/external sounders).
74: Level C Entry Time
This Command has been replaced by Command 203.
75: Level/Partition C Exit Time
This Command sets the Exit Time for Level or Partition C.
Option
1 10 seconds
2 20 seconds (default)
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds