Testing i-on40
Page 92
2. Press >.
The bottom line of the display shows “IP Link Status”.
3. Press >.
The bottom line of the display shows “OK” if the
control unit has successfully connected to a PC by
way of an Ethernet cable.
4. Press < then n.
The bottom line of the display shows “IP Address”.
5. Press >.
The bottom line of the display shows the IP address
currently assigned to the built-in Ethernet port. Note
that this may have been assigned by DHCP.
6. Press < then n.
The bottom line of the display shows “Subnet Mask”.
7. Press >.
The bottom line of the display shows the current
subnet mask. Note that this may have been assigned
by DHCP.
8. Press < then n.
The bottom line of the display shows “Gateway
Address”.
9. Press >.
The bottom line of the display shows the current
gateway address. Note that this may be blank if you
are connecting a PC/laptop directly to the control
unit.
10. Press < then n.
The bottom line of the display shows “MAC address”.
11. Press >.
The bottom line of the display shows the MAC address
used by the built in Ethernet port.