i-on40 Appendix I
Page 97
Enabled
Static Test Call:
Disabled
(See Note 3)
Burg Comms Rearm:
Disabled
21CN FF Ack Time:
800ms
Static Test Call:
Disabled
SPEECH DIALLER:
Call mode: Disabled
Speech Messages
: None
Speech Phone book
: Empty
Triggers
: None
Destinations
: None
Call Acknowledged: Enabled
SMS:
Call Mode: Disabled
Messages: Blank
Phone Book: Empty
Triggers: None
LINE FAIL RESPONSE:
Silent
LINE FAIL DELAY:
9s (see Note 2)
IP NETWORK (OWN):
Web Server Status: Disabled
Web Server Port Number: 80
IP Address: 192.168.0.100
IP Sub-net mask: 255.255.255.0
Gateway IP address: Blank (this option
appears only if Ethernet module fitted)
DOWNLOADING
Account
Name: Blank
Serial Number: Blank
Rings to Answer:
5
Answer on 1 Ring:
Disabled
Access Mode:
Call Out Only (see Note 2)
Phone Book:
Blank
IP Network:
IP Address 1: Blank
IP Port 1: Blank
IP Address 2: Blank
IP Port 2: Blank
Secure Callback:
Disabled
Modem Baud Rate:
Auto
Note: 1. DD243 is a UK requirement. If
this option is disabled in non-UK
countries then the control unit
will still comply with EN51031.
2. This setting is required in
order to comply with EN50131.
3. To comply with EN50131,
either Static or Dynamic test
calls must be enabled. This is
available only when an i-sd02 is
fitted and ARC Communications
enabled.
4. For INCERT approval set to
NO.