i-on40 Installer Mode Programming
Page 65
CID/SIA Events
(This menu appears only if you select “Contact ID” or any
of the SIA versions in Communications - Report Types. See
Appendix II for a description of the CID and SIA formats.)
To make programming easier, the i-on40 groups CID/SIA
telegrams together into Report Groups. Table 3 lists the
telegrams included in each report group, and the relevant
CID/SIA codes. When you enable a Report Group, then
you are enabling the control unit to send any of the
telegrams in that group.
CID/SIA alarm transmissions will take considerably more
telephone time than Scancom Fast Format since the
system transmits extended alarm data to the ARC.
Note: The control unit delays reporting/logging either
mains loss, or leaving Installer Menu with mains loss,
by 15-22 minutes (chosen randomly). The control
unit delays reporting/logging either mains restore, or
leaving Installer Menu with mains restored, by 60-90
sec (chosen randomly).
Table 3. CID/SIA Report Groups
Code
Report Group Includes: CID SIA
Fire Alarm Fire and fire restore 110 FA, FR
Zone PA and restore 120 PR Panic Alarm
Keypad PA, Keypad PA restore
RF PA, RF PA restore
Radio keypad PA, radio keypad PA
restore
121 HA
Burglar Alarm Burg and Burg restore 130 BA, BR
Technical Alarm Technical alarm and restore 150 UA
Keypad tamper and restore
Detector tamper and restore
Lid tamper and restore
Bell tamper and restore
Radio keypad tamper and restore
External siren tamper and restore
137 TA, TR
Tampers
User code tamper 461 JA, JV
Set/Unset System arm and disarm 401 OP
Part Set System part set 401 CL
Reset System reset 305 OR
Exit Timeout Exit timeout and restore 457