i-on40 Installer Mode Programming
Page 29
Deleting a WAM
To remove a WAM from service in the system, then:
1. Select Detectors/Devices – WAM – Add/Del WAM.
The bottom line of the display shows the first in a list
of the available WAMs.
2. Press u or n to select the WAM you wish to delete
then press Y. (When a slot is occupied with a WAM
then the bottom line shows a “*” at the beginning.)
The display asks you to confirm your choice.
3. Press Y.
The control unit deletes the WAM’s identity from the
selected memory slot.
Outputs
The i-on40 control unit provides three different sets of
outputs:
8 radio outputs. To use these outputs you must install
a radio receiver, for example a WAM, 762 or 768.
4 hardwired outputs.
12 plug-by outputs.
(See i-on40 Installation Guide for the position of
connectors.)
All three sets of outputs can be programmed as any of
the output types listed on page 34.
Radio Outputs
To use a radio output on a WAM see page 27 .
To use a radio output on a 762r, 768r or 769r receiver
you must teach the identity of the i-on40 control unit to
the receiver.
Note: If you are teaching 762r, 768r, or 769r receivers
then make sure that you disable IR learn on the
receivers first.
Adding Radio Outputs
To teach the control unit's identity to a 762r, 768r or
769r: