i-on40 Appendix III
Page 103
Partition and Other Programming
Menu Sub Menu Option
Add/delete Detectors/Devices External Radio Siren (if to be
fitted)
Wired keypads Keypad 01 Name = Office
Partition 3
Keypad 2 Name = Factory
Partition 2
Keypads 3 & 4 – not fitted NA
Outputs Panel Outputs 1 = Siren
2 = Strobe
3 & 4 = NU
Partitions P1 Name = Foyer
Exit Mode = Final Door Set
Settle Time = 10s
Entry Time = 45s
Alarm Response = Siren +
Comms (Full)
Strobe on Set = Yes (If required)
Strobe on Unset = Yes (if
required)
P2 Name = Offices
Exit Mode = Timed
Exit Time = 20s
Entry Time = 45s
Alarm Response = Siren (Local)
P3 Name = Factory
Exit Mode = Timed
Exit Time = 20s
Entry Time = 45s
Alarm Response = Siren (Local)
Full Set Link P2 = Yes
P3 = Yes
System Options Wired Zone Type Select FSL if using all wired
detectors
DD243 (for UK only) Confirmation = On
Confirmation Time
30 mins
After Entry
2 zones
Entry keypad Lock
On
Sounder on
Unconfirmed
Siren on
Unconfirmed
Unconfirmed reset
User
Confirmed Reset
Installer
Keypad Text Enter Name of installer company
Siren Delay (default 0 mins)
Siren Time (default 15 mins)
Force Set Off
CSID Enter 4 digit ARC Scantronic reset
code (if required)
Silence Alerts User