Cooper Security i-on40 Guía de instalación Pagina 108

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 116
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 107
Appendix III i-on40
Page 104
User Programming
User Code Type Partitions
01 1234 Master User Whole system – P2 + P3
02 2222 Partition user P2 (Factory)
03 3333 Partition user P3 ( Office)
User Operation
To set:
Full System
User 01 enters code or Prox + 3
(User 01 can select an individual Partition
or full set the whole system.)
Factory only
(Partition 2)
Partition 2 User enter Code or Prox in
Keypad 2
Office only
(Partition 3)
Partition 3 User enter Code or Prox in
Keypad 1
To Unset:
First user to enter keys in their code or
presents a Prox tag
If User 02 (a member of the Factory department) sets
their Factory partition and the Office partition is already
set, then the common foyer area will also start to set.
When the user closes the Front Door (zone 1) the whole
system sets and the alarm response is raised to Full
alarm (Siren + Comms).
The same thing will happen if User 03 sets the Office
partition when the Factory partition is already set.
If either User 02 or 03 opens the Front Door this starts
the entry time and tone. The user enters their code or
presents a Prox tag to the keypad in their department.
The system then unsets their partition and the common
area.
If the Master user opens the Front Door and enters their
code or presents a Prox to a keypad then only P1, the
common area, will unset. The keypad then gives the
master user the option to unset either Factory or Office or
both. This allows the manager to open only the area they
want to enter, leaving the other area protected.
Vista de pagina 107

Comentarios a estos manuales

Sin comentarios