Installer Mode Programming i-on40
Page 52
Entry Keypad Lock
This option determines whether the user can unset
the system by entering an access code after opening
the entry door.
Off: The user can enter an access code at the keypad
after the entry door opens (used for DD243:2004
clause 6.4.4).
On: The user must unset the system by some means
other than the keypad, for example prox tag or
remote control (used for DD243:2004 clause 6.4.5).
Note: This option functions when confirmation is ON and
communications is enabled. If communications is
disabled this option has no effect.
Sounder on
Unconfirm: When the system is set the control unit
activates the internal sounders when an unconfirmed
alarm occurs.
Confirm: When the system is set the control unit
does not activate the internal sounders until a
confirmed alarm occurs.
Siren on
Unconfirm: the control unit operates the siren for all
alarms (and overrides any Siren Delay).
Confirm: When the system is set the control unit
does not activate the siren(s) until a confirmed alarm
occurs.
Unconfirmed Reset
If you enable alarm confirmation then this option
overrides System Options - User Reset – Zone Alarms (see
page 50). You may then use the options below:
User: The user can reset after an unconfirmed alarm.
Installer: The user cannot reset after an
unconfirmed alarm, the installer must do it.
Note: If a user causes an alarm which would require
Installer reset then they have 90s to abort the alarm,
which they can then reset themselves.
Confirmed Reset
If you enable alarm confirmation then this option
overrides System Options - User Reset – Zone Alarms (see