1. Introduction
497096, issue 3 Page 3
Using Programming and Testing Commands
When delivered from the factory, the control unit already has default settings.
To change the default settings:
1. Enter installer mode.
2. Key in the appropriate command number and press y.
The display shows the current value of the command.
3. Key in digits to select the value you require.
The display shows the new value.
4. Press y to store the new value of the command.
Note: If at any time you change your mind, repeat steps 1 to 3. The 9x5x Quick Reference
Programming Guide shows the commands and their values. "Y" to the right of a
value shows that it is the factory default.
Leaving Installer Mode
When you have finished programming the control unit:
1. Press 99y at the keypad
The display shows:
99:Exit Eng ?
2. Press y.
The display shows:
99:Checking Sys
followed by the time and date.
The system is now in user mode.
Note: If any 24-hour, Fire, PA or Technical zones are active when you enter Command
99, the keypad gives an error tone and displays the faults. Correct the problems
identified. When the display shows "No Faults", press
y
to enter user mode.
Restoring Default Access Codes (first stage reset)
The default (original) access codes are:
4-digit 6-digit
Engineer Code 7890 567890
Access Code User 1 1234 123456
Access Code Users 2 to 50
X002 ... X050 X00002 ... X00050
Duress Code
X017 X00017
Note: To activate the Access Codes (02 to 50) and Duress Code, which are initially
inactive, User 1 must change the defaults to the correct codes.
The 9x5x User Guide explains how to do this.