2. Programming Commands
497096, issue 3 Page 37
05 Walk Test: active during both engineer and user Walk Tests and
during the time between silencing and resetting the system. It is used
on movement detectors that are able to switch off the Walk Test lamp
in any state other than a Walk Test.
06 Ready Lamp: active when the system is unset and if there are no
faults. It is inactive when the system is full or part set, during any
alarm or if a circuit fault prevents setting. It is also active when the
control unit is in installer mode.
07 24-hour Alarm: activated when a zone designated as 24-hour is
violated and deactivated when the system is disarmed.
08 Strobe: activated during an alarm and deactivated when the system is
disarmed.
09 Smoke Reset: designed to be connected to low-voltage smoke
detector reset terminals. It is active for 3 seconds when the system is
reset after an alarm.
10 Siren Test: activated when the user performs a sounder test.
11 Strobe Set A: active for 10 seconds after the system (or any partition)
is set. It can be used to operate the Strobe output to give a visual
indication that the system has completed setting.
12 Pulse Set 1: active for the time set by Command 170 when someone
sets the system (same as type 26).
13 Pulse Unset 1: active for the time set by Command 172 when
someone unsets the system and during a Fire alarm or PA (same as
type 30).
14 Alarm Confirm: active during a confirmed alarm.
15 Set Complete: active for 10 seconds after someone sets the system.
16 Unset Complete: active for 10 seconds after someone unsets the
system or disarms it after an alarm.
17 System Alarm: activated when the control unit raises a System Alarm.
In a partitioned system, the following options (18-25) are also available:
18 Bell Partition A: active when an alarm occurs in Partition A.
19 Bell Partition B: active when an alarm occurs in Partition B.
20 Bell Partition C: active when an alarm occurs in Partition C.
21 Bell Partition D: active when an alarm occurs in Partition D.
22 Strobe Set A: active for 10 seconds after Partition A is set.
23 Strobe Set B: active for 10 seconds after Partition B is set.
24 Strobe Set C: active for 10 seconds after Partition C is set.
25 Strobe Set D: active for 10 seconds after Partition D is set.