2. Programming Commands
497096, issue 3 Page 57
143: Contact ID Report Restores
If the Reporting Type is set to Contact ID (Command 103, option 1), use this
command to select the types of contact ID messages that will be sent.
Option
0 Basic: all the messages with numbers in the "CID Code" column of the
table in "131: SIA Report Mode", except for those marked with an "‡".
1 Basic + Restore (default): all the messages with numbers in the "CID
Code" column of the table in "131: SIA Report Mode".
Note: If the keypad display shows "Custom" when you enter Command 143, Downloader
has been used to program Contact ID Report Restores.
144 to 150: Not used
These commands are not used.
151 to 158: Plug-by Communicator Outputs
These commands select types for the control unit's programmable outputs,
which can be used to control a plug-by communicator. All models provide
eight programmable outputs on the main circuit board and there is an optional
expansion for the 9853 that adds four more (see Commands 211 to 214 on
page 68). The outputs can be connected to the communicator by a wiring
harness provided with the control unit (refer to the 9x5x Installation Guide for
details). The commands take two digits to select the type (23-26 apply to a
partitioned system only) and have the following defaults:
Command Output Default type
151 1 01 Fire
152 2 02 PA
153 3 03 Burglar
154 4 04 Open/Close
155 5 15 Zone Omitted
156 6 05 Alarm Abort
157 7 07 Alarm Confirm
158 8 06 Technical Alarm
211 9 11 AC Fail
212 10 21 Battery Fault
213 11 40 All Fault
214 12 12 Tamper Alarm