2. Programming Commands
497096, issue 3 Page 65
Option
00 Not Used 21 Battery Fault
01 Fire 22 System Alarm
02 PA 23 Alarm Partition A
03 Burglar 24 Alarm Partition B
04 Open/Close (Note 1) 25 Alarm Partition C
05 Alarm Abort 26 Alarm Partition D
06 Technical Alarm 27 Not used
07 Alarm Confirmation 28 Not used
08 RF Low Battery (Note 2) 29 Not used
09 Supervision Loss 30 Pulse Set OP 1
10 RF Jamming 31 Pulse Set OP 2
11 AC Fail 32 Pulse Set OP 3
12 Tamper Alarm (day tamper) 33 Pulse Set OP 4
13 Open (Note 1) 34 Pulse Unset OP 1
14 Close (Note 1) 35 Pulse Unset OP 2
15 Zone Omitted (Note 3) 36 Pulse Unset OP 3
16 Medical Assistance 37 Pulse Unset OP 4
17 Key Box 38 Set Fail
18 Anti-Mask 39 General Fault (Note 4)
19 Smoke Detector 40 All Fault (Note 5)
20 Comms Acknowledge 41 Duress
Notes:
1. 13 Open and 14 Close provide the same functions as 4 Open/Close, but on two
separate channels.
2. The control unit sends 08 RF Low Battery when the radio detector with a low
battery causes an alarm or sends a supervision signal. To enable this facility in day
mode set Menu 37 to option 1.
3. 15 Zone Omitted – the control unit sends this signal for five seconds when a user
omits a zone.
4. General Fault is active for all faults except AC Fail, Anti-Mask, Battery Fault, Line
Fault, Supervision Fail, Zone AC Fail, Zone Battery Fault and Zone Low Battery.
5. All Fault is active for all faults (including AC Fail, Anti-Mask, Aux DC, Battery Load
Test Fail, Battery Missing, Comms Fail, Jamming, Keypad Ident Fail, Line Fail, Low
Battery, Plugby Fail, RF Low Battery, Supervision Fail, Telecommand Low Battery,
uCom Fail, Zone AC Fail, Zone Battery Fault, Zone Fault, Zone Low Battery and
Zone Pwr O/P).
6. The control unit delays reporting/logging either mains loss, or exiting engineering
with mains loss, by 15-18 min (chosen at random). If you select a Scandinavian
country in Command 0, the control unit waits at least 60 minutes before reporting.
199: Display Zone Circuit Resistance
For information on this command, see page 74.