2. Programming Commands
Page 60 497096, issue 3
162: External Sounder on Confirmed or Unconfirmed Alarm
Note: Set Alarm Confirmation (Command 89) to 1 or 2 to access this command.
This command selects whether the control unit will operate the external
sounder for a confirmed alarm or for an unconfirmed alarm.
Option
0 Control unit operates the external sounder for a confirmed or
unconfirmed alarm (default).
1 Control unit operates the external sounder only for a confirmed alarm.
Note: Compliance with DD 243: 2004 (see page 83) requires that Command 162 is set to 0.
163: Confirmed Alarm during Entry
Note: Set Alarm Confirmation (Command 89) to 1 or 2 to access this command.
This commands controls how the system treats alarms that arise during entry.
The options select the number of non-Entry Route zones that must be
triggered to provide a confirmed alarm after the entry time.
Option
0 Never (default). Alarm Confirmation is disabled after entry.
1 One zone.
2 Two zones.
Notes:
1. Compliance with PD 6662 / prEN 50131-1: 2004 (see page 85) requires that
Command 163 is set to 0.
2. Compliance with DD 243: 2004 (see page 83) requires that Command 163
is not set to 1 (setting to 0 to comply with Note 1 is acceptable).
Option 0 ensures that you will never get a confirmed alarm after the start of
the entry timer. Select this to comply with DD 243 sections 6.4.2, 6.4.3, 6.4.4
and 6.4.6, which cover entry methods where:
° Unlocking the final door unsets the system.
° Unlocking the final door disables confirmation.
° Opening the entry door disables confirmation.
° The user must call the Alarm Receiving Centre (ARC) to unset the system.
Select option 2 to comply with DD243: 2004 section 6.4.5, which covers
unsetting the system with an item of portable alarm communication equipment
(for example, a proximity reader or telecommand).