2. Programming Commands
Page 26 497096, issue 3
54: Supervision Time
Radio zones are supervised. If they do not communicate for a certain time,
the control unit reacts in the way selected with Command 55. The time is
based on the supervision period of the radio detector used in the zone, which
depends on the model as shown in the following table. The model number is
usually shown on a label affixed to the PCB inside the detector.
Long period (29 minutes) Short period (4 minutes)
1715REUR-00 1715REUR-02 735REUR-01
715REUR-00 715RB-00 RST15RDK-00
715RUK-00 715REUR-02 RST19RDK-00
719REUR-00 715REUR-01 RST35RDK-00
735REUR-00 719RB-00 all 734R models
719REUR-02 735REUR-50
719REUR-01 all 714R models
735RB-00 all 738R models
735REUR-02 all 739R models
735REUR-03 all 7525R models
Command 54 specifies whether the control unit uses slow or fast supervision,
which determines how quickly it reacts to losing contact with a radio zone. It
will never take more than two hours to react to a supervision failure.
Option
0 Supervision time slow.
1 Supervision time fast (default).
If the system uses any radio detectors with long supervision periods, select
option 0.
If the system uses only radio detectors with short supervision periods, you
can select either option. However, selecting option 1 will cause the control unit
to react to a loss of contact after only about 15 minutes.
Note:
1. Compliance with PD 6662 / prEN 50131-1: 2004 Grades 1 and 2 (see page 85)
requires option 1.
2. PD 6662 / prEN 50131-1: 2004 Grade 3 does not permit radio zones.