2. Programming Commands
497096, issue 3 Page 31
65: Level/Partition B Exit Time
This command sets the Exit Time for Level or Partition B.
Option
1 10 seconds
2 20 seconds (default)
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
66: Forbikobler Keypads and Partitions
If you created a partitioned system during initial power up, this command
enables you to assign individual Forbikobler keypads to those partitions. By
default, all Forbikobler keypads belong to all partitions.
Note: Command 32 is used to assign ordinary keypads to partitions.
67: Forbikobler Approved
This command specifies whether the Forbikobler system should operate in an
approved manner (user codes only) or a non-approved manner (proximity
tags and user codes).
Option
0 Non-approved
1 Approved (default)
68: Forbikobler Door Timer
This command sets the time that the Forbikobler system allows for entry to
the building (not the time needed to unset the system). During this period, an
optional output is activated to operate an electromechanical lock on the door.
Option
0 2 seconds 5 20 seconds
1 3 seconds 6 30 seconds
2 4 seconds 7 60 seconds
3 5 seconds (default) 8 120 seconds
4 10 seconds 9 255 seconds
Comentarios a estos manuales