2. Programming Commands
Page 14 497096, issue 3
21: Zone Configuration
This command enables you to select the wiring type of the zone connectors
on the control unit PCB. The default is option 0 for all models.
Zones type on 9751/2 PCB
0 Up to 8 closed circuit loop zones (CC + Com A/T).
1 Up to 8 fully-supervised loop zones (FSL 2K2/4K7)
.
Zones type on 9853 PCB
0 Up to 8 closed circuit loop zones (CC 4 wire).
1 Up to 8 end-of-line zones (EOL 2K2)
.
2 Up to 16 fully-supervised loop zones (FSL 2K2/4K7). This setting
enables up to 24 zones to be connected to expanders.
3 Up to 8 fully-supervised loop zones (FSL + EXP). This setting enables
up to 32 zones to be connected to expanders.
Note:
1. Compliance with PD 6662 / prEN 50131-1: 2004 (see page 85) at Grade 3 (9853
units only) requires that Command 21 is set to one of the Fully Supervised Loop
options (2 or 3).
2. Using three-resistor anti-mask wiring (9853 units only) requires that Command 21 is
set to one of the Fully Supervised Loop options (2 or 3).
You can connect more zones using expanders. The maximum number of
zones depends on the type of control unit. Refer to the Installation Guide for
details.
22: Loudspeaker Chime
In a single system, a user may find that the Chime tone from the keypads is
not loud enough. If so, use this command to make the internal sounder give
the Chime tone as well. If you select option 0, the internal sounder emits no
tone. Select a value from 1 (quietest) to 9 (loudest) to set the Chime volume
(the default is 5). The internal sounder demonstrates the volume when you
enter the digit.
Note: In a partitioned system, this command is available only for Partition A.