2. Programming Commands
Page 36 497096, issue 3
81 to 84: Output n Type
These commands, along with Commands 215 to 218, select types for the
control unit's panel outputs. They take two digits to select the type (see below)
and have the following defaults:
Command Output Control unit Default outputs
81 1 All 00 Bell
82 2 All 08 Strobe
83 3 All 03 Set Latch
84 4 9853 04 Shock Sensor Reset
215 5 9853 15 Set Complete
216 6 9853 16 Unset Complete
217 7 9853 38 All Fault
218 8 9853 01 EE Follow
Notes:
1. Commands 84 and 215-218 apply only to the 9853, as only it has more than three
outputs.
2. The panel outputs can be tested using Command 91 (page 73).
Option
00 Bell: active during an alarm. Use Command 41 to set Bell Delay and
42 to set Bell Duration. In a partitioned system, this type is activated
when any partition is in alarm. If Alarm Confirmation (Command 89) is
enabled, use Command 162 to set whether the bell is sounded on the
first or confirmed alarm.
01 EE Follow: active when Entry or Exit Time starts and inactive when
the time expires or is terminated. The output can be used for a
separate Entry/Exit buzzer. It will not give a tone during part set if the
exit mode is silent set or instant set.
02 Armed Lamp: active continuously while the system is full or part set.
03 Set Latch: active when the system is set and inactive when the
system is unset or an alarm condition occurs. It is active for one
second when a reset is performed or the control unit leaves installer
mode. It is also active during Walk Tests.
04 Shock Reset: used to reset shock sensors (for example, the "Viper").
The output is triggered by the control unit at the start of the Exit Time
and remains active for five seconds.