2. Programming Commands
Page 64 497096, issue 3
185: Keyswitch Auto Reset
This command instructs the control unit to reset automatically if the user uses
the keyswitch to set the system on leaving.
Option
0 Off (default). User must reset manually.
1 On. System resets automatically when the user sets it with a
keyswitch (KM or KF).
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 85) requires that
Command 185 is set to option 0.
186: Set Number of Home Beep Calls
This command sets the number of times that the control unit will call if
Reporting Type is set to Home "beep" (Command 103, option 6). The
repeated message acts as a confirmation.
Enter two digits, from 01 to 15 (default 02). The default is usually sufficient,
providing one call to alert the user and a second call to confirm the alert. For
the 9853 only, the user can acknowledge the call by pressing 5 on the
telephone handset; this terminates the series of home "beep" calls.
Note: This command sets the number of successful calls the system makes. It does not
include retries after failed communication attempts, which are built into the general
protocols used to control communications.
187 to 190: Not used
These commands are not used.
191 to 198: Fast Format Channels
If Fast Format reporting is selected (Command 103, option 0), Commands
191 to 198 enable you to assign types of events to outputs. The commands
take two digits to select the type (23-26 apply to a partitioned system only)
and have the following defaults:
Command Output Default type
191 1 01 Fire
192 2 02 PA
193 3 03 Burglar
194 4 04 Open/Close
195 5 15 Zone Omitted
196 6 05 Alarm Abort
197 7 07 Alarm Confirmation
198 8 06 Technical Alarm