2. Programming Commands
Page 42 497096, issue 3
102: Communication Fault Timeout
This command sets the period after which a communications fault times out.
In earlier versions of the 9x5x series, timeouts occurred after a specified
number of calls.
Option
0 60 seconds
1 120 seconds
2 240 seconds (default)
3 480 seconds
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 85) requires that
Command 102 is set to option 2.
103: Reporting Type
The system supports several message formats for communications:
Option
0 Scancom Fast Format (FF) (default)
1 Contact ID (CID)
2 Scancom SIA Level I (SIAI)
3 Scancom SIA Level II (SIAII) – this does not send time and date
4 Scancom SIA Level 3 (SIA3)
5 Extended Scancom SIA Level 3 (XSIA3)
6 Home "beep" (Home)
Option 6, Home "beep", is not a particular message format. What it means is
that the communicator dials a number and sends a "beep" down the line. This
does not allow a complex message to be sent but means that the person
answering the call needs no special equipment to decode the message. The
number of times the communicator repeats the Home "beep" is set with
Command 186. For the 9853 only, the receiver can press 5 on the telephone
keypad to acknowledge the alarm and terminate the series of calls.
104: Not used
This command is not used.