5. Testing
5. Testing
Reading the Log (Command 90)
The control unit keeps a log of recent events The log can contain up to 500
events. Each event is represented by a short text message, shown below
and on the next page. To review the event log, make sure the system is in
programming mode, then:
1. Key in 90 .
The display shows the most recent event in the log. For a list of the log
messages see below.
2. Key in 1 to show earlier events or 3 to see more recent events.
3. Key in 0 to print the log if there is a printer attached to the system.
4. Key in 7 to toggle a logging printer on or off. (The keypad gives a chime
tone when switching the logging printer on, and a "beep beep" confirm
tone when switching the printer off.)
5. Press to toggle between the event message and the event time.
6. Press to leave the log.
The table below and on the next page shows all the messages that can
appear in the event log. The left hand column shows the messages that
appear on a keypad display. The middle column shows the corresponding
messages that appear in a printed log. Note that each event in a printed log
is preceded by the date and time in numerical format.
Note that neither the Installer nor the user can erase the log.
In the log user codes are represented by numbers as follows:
U00 Installer U19 Idle
U01 User code 1 U20 Telecommand
... ... U21 Keyswitch
U16 User code 16 U22 Remote Reset
U17 Duress code U23 Download
U18 Control Unit U24 Virtual keypad