4. Programming
38 496791
To change: Key-in: Notes Default
Level D Entry Time 78 1 10 seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Level D Exit Time 79 1 10 Seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Output 1 Type, one of 81 n
Where n is one of the following:
00 Bell (default full/part set sys.) 13 Pulse Unset
01 EE follow 14 Alarm Confirmation
02 Armed lamp 15 Set Complete
03 Set latch 16 Unset Complete
04 Shock sensor reset Partitioned System
05 Walk test 17 Bell Partition A
06 Ready lamp 18 Bell Partition B
07 24 hour alarm 19 Bell Partition C
08 Strobe 20 Bell Partition D
09 Smoke sensor reset 21 Strobe Set Partition A
10 French Siren Test 22 Strobe Set Partition B
11 Strobe Set (any Partition) 23 Strobe Set Partition C
12 Pulse Set 24 Strobe Set Partition D
Output 2 Type, one of 82 0 Bell
See Command 81 for a list of options. Default for Command 82 in full/part set
sytem is 08 Strobe. Default in partitioned system is 14 Bell for Partition B.
Output 3 Type, one of 83 0 Bell
See Command 81 for a list of options. Default for Command 83 in full/part set
system is 03 Set latch. Default in partitioned system is 15 Bell for Partition C.
Output 4 Type, one of 84 0 Bell
See Command 81 for a list of options. Default for Command 84 in full/part set
system is 03 Set latch. Default in partitioned system is 16 Bell for Partition D.
Burg Comms Rearm 85 0 Latch Y
1 Rearm
Dual Ply Entry 86 0 Off Y
1 On (not recommended in U.K.)
Dual Key Alarm 87 0 Off Y
(Incl. keyswitch PA) 1 On