4. Programming
496791 39
To change: Key-in: Notes Default
Alarm Confirmation 89 0 Confirm off (default for rest of World) Y
1 Confirm on (default UK only)
Event Log* 90 0 Print log
1 View earlier events
3 View later events
7 Toggle printer on/off
8 Print configuration
Cancel viewing
Toggles time/date display
Test Output 1* 91 Output 1 operates, press or to end
test.
Test Output 2* 92 Output 2 operates, press or to end
test.
Test Output 3* 93 Output 3 operates, press or to end
test.
Test Internal Sounder 94 Internal sounders operate, press or to
(Single system only.) end test.
Test Keypad Sounder 95 Keypad sounders operate, press or to
end test.
Test Output 4* 96 Output 4 operates, press or to end
test.
Engineer Walk Test* 97 Zn indication and chime operate when
* See “5. Testing”
cct open
(Clear) End walk test
Load Defaults 98 1 Load defaults
Leave Programming 99
Communications Programming
To change: Key-in: Notes
Default
Call Mode 101 0 Disabled Y
1 Single
2 Alternate
3 Dual
Reporting Type 103 0 Fast format Y
1 Contact ID
2 SIA I
3 SIA II
4 SIA 3
5 Extended SIA 3
Comentarios a estos manuales